SleepSign™ for Animal

Sleep Analysis Software

  • SleepSign helps you to evaluate the different sleep stages of animals(rat, mouse, dog, etc.).
  • SleepSign has 3 unassigned vigilance stages in addition to the regular pre-assigned sleep stages(Wake, REM, SWS, etc.).You can assign these vigilance stages as required in your research.
  • SleepSign automatically evaluates sleep stages based on EFG and EMG signals.You can also easily evaluate sleep stages by visually checking the waveforms on the screen.
  • SleepSign can display various types of information, such as Hypnograms and Trend Graphs.
  • SleepSign has various analyzing functions, including Stage Graphs, Vigilance State Parameters Display, FFT analysis, digital filter, and zooming.

NOT FOR THE MEDICAL USE

FEATURES

feature_SleepSign

DATA ACQUISITION

A/D CONVERTING FUNCTION

SleepSign can continuously record physiological signals up to 32 channels for a long period of time (with certain limitations for sampling frequencies).

    Data1_SleepSign

    Recording

  • With the A/D converting function, SleepSign can record analog signals to a maximum of one week.
  • In addition to EFG and EMG, it can also record analog signals such as EOG, Body tempreture and Blood pressure.
  • SleepSign displays the raw data with the trend-graph (the maximum, minimum, average, and integral graphs calculated from the recording data of any time bin) in real time.

    You can easily grasp the change of the Integral EMG and body temperature.

DATA ANALYSIS

WAVEFORM VIEWER

Data2_SleepSign

  • SleepSign can display to the maximum 32 channels of waveforms.

    It displays the raw data as the numerivcal value or character, in addition to displaying the line as waveform.

    This function is convenient to display data of small changes such as body temperature blood pressure etc.

  • A waveform window can be divided horizontally into 3 or 5 parts.

    The waveform of the previous page and the page after can be displayed on one screen with this function. Also,
    it can display data up to 1 hour on one screen.

  • You can always display a spectrum corresponding to EFG data and use it as the index for manual scoring.

STAGE SCORING

You can score the sleep stages from EFG and EMG signals automatically or manually.

Data4_1_SleepSign

    Automatic scoring

  • The algorithm of the automatic scoring can be modified manually.
  • The automatic scoring of SleepSign has a search function for multiple stages.

    All of the condition divergences that you set up are computed form the biggining to the end. If there are some stages that meet a condition other than the first applicable stage, SleepSign will memorize rhem as the next candidate, and make a list of these epochs.

    After the automatic scoring, you can also correct the these epochs visually by checking the test.

  • SleepSign has the function to detect artifact signals by seting the threshold level. These artifact epochs can be exclude from average spectrum analysis.
  • Manual scoring

    • You can carry out scoring easily by using the keybord or mouse and score continuous epochs with one action of the mouse.
    • SleepSign can memorize 2 previous the stages that are changed manually, so, the history of the modification of the stages can easily reviewed.

    OTHER SLEEP ANALYSIS

    Data4_2_SleepSign

      Hypnogram & Trend Informetion

      • You can divide hypnogram windows to up to 12 partitions.

        This is convenient to analyze the sleeping data collected for a long period “Trend Window” (displays hypnograms) and “Workspace Window” (displays spectirums) can be separated from the Waveform Viewer.

      • SleepSign can display trend graphs on the same scale as the hypnogram. The Trend Window can display other information such as percentage of FFT pressure, LF/HE of the EKG, etc.

      Stage Graph

      • You can tell the occurrence-rate and total time of sleep stages for any time bin.

      Vigilance Stage Parameters

      • With the Vigilance State Parameters function, you can obtain the number and duration of the sleep stages in selected periods.

      Frequency Analysis

      • SleepSign has various frequency analytic function:
      • FFT analysis on each or all epochs either for an epoch or page can be displayed.
      • Average Spectrum for each sleep stage can also obtained.

    OUTPUT

    Data4_3_SleepSign

    Text data outputs

      • You can output various analysis results (spectrum, trend information, hypnogram etc.) as numerical values to the clipboard and text files.

        You can also output the result of the data analysis directly to MS-Excel etc. by text output function.

      Print

      • You can print waveforms, hypnograms, and the result of other analysis can also be output as files. You can futher edit or print the results of analysis by using other applications (MS-Excel etc.).

SPECIFICATION

DATA COLLECTION

A/D CONVERTING FUNCTION

Channel NumbersMaximum 32 channels
Sampling FrequencyFrom 100 To 1000[Hz]
(A certain limitation for the sampling frequency depends on the CPU)
Recording TimeMaximum 1 Week
(Depends on the free space of the hard disk)

DATA ANALYSIS

SCORING OF SLEEP STAGES

Sleep StagesSleepSign has 3 unassigned stages except for regular preassigned sleep stages (Wake, REM, SWS, etc.)
Epoch length4, 5, 8, 10, 12, 15, 20, 30, and 60[second]
Minimum required signalsEFG : 1ch, EMG : 1ch (Capabilities to include EOG signals)
Waveform RecognitionDelta-wave, Theta-wave. IEMG(Integrated EMG), (REMs Counts in EOG)
Method of ScoringThis software determines sleep stages by the condition divergence.

COMPUTER HARDWARE REQUIREMENTS

OSWindows XP or higher
CPUPentium2 400MHz or higher processor
(600MHz or higher is recommended)
RAM128MB or higher
(256MB or higher recommended)
Hard Disk100MB or higher free space
(1GB or higher is recommended)
Resolution1024 x 768 or higher

OTHER

A/D Congerting Board
Note : A signal connection cable need to be purchased separately
CONTEC MICROELECTRONICS USA INC.
AD16-16U(PCI) EV (16 chanel, 16bit, (+-)10V, (+-)5V)
AD16-32/2(PCI) F (32 chanel, 16bit, (+-)10V, (+-)5V, (+-)2.5V)
AD16-32/2(CB) F (32 chanel, 16bit, (+-)10V)(for laptop PC)
Third party data import BioPac AcqKowledge data file
DSI Data Quest Art data file
EDF (European Data Format) file
Text file
PrinterAny printers work with the OS listed above.
Expansion Storage DevicesThe use of recording data storage is recommended.
DVD-RAM, etc. (There is no limitation if it works with OS listed above.)

ARCHITECTURE DIAGRAM OF SYSTEM

The whole recording system consists of the software, SleepSign, and hardwares with an A/D conversion board.

Data5_SleepSign


NOTE:SleepSign is software only. (Personal computers, and other pieces of hardware are not included.)

Developed by KISSEI COMTEC Co., LTD.(JAPAN)